Skip to navigation – Site map

HomeNuméros33 (suppl.)Methods and innovationsTesting the use of geostatistical...

Methods and innovations

Testing the use of geostatistical and statistical methods to improve data visualization.
Case study on GPR survey of Tarragona Cathedral

Robert Tamba, Roger Sala and Ekhine García
p. 335-338

Full text

Introduction

1The paper presents the results of the use of alternative geostatistical and statistical methods to enhance visualization of the Tarragona Cathedral. These methods improve data homogeneity with time/depth, give alternative time-slice computation using other values than the mean value, and study the impact of the time-window thickness used when generating time-slices. The data used for the project was a GPR prospection of the cathedral accomplished in 2007 by Roger Sala and Ekhine Garcia (SOT Prospecció arqueològica) for the Tarragona Cathedral geophysical research project funded by I.C.A.C. (Catalan Institute of Classical Archaeology). The survey was conducted by a multidisciplinary team coordinated by archaeologist Josep Maria Macias (ICAC) and Dr. Albert Casas (Universitat de Barcelona) with the participation of Dr. Pietro Cossentino’s team (University of Palermo) and the SOT Archaeological Prospection Team. Based on ten years of archaeological research (by J. Menchón, I. Teixell, A. Muñoz, J.M. Macías), three different geophysical techniques were employed. The project was coordinated by Casas’s team, which was in charge of the 2D electrical tomography and the subsequent 3D integration. Cosentino’s team operated 3D electrical tomography and low frequency GPR (100MHz). The SOT team completed an extended georadar prospection. The objective was to search for possible archaeological remains in the first two meters below ground surface in order to give archaeologists the opportunity to integrate the results of different vertical and horizontal scales given by electrical tomography.

Prospection methodology

2The area of prospection covered the nave and aisles and the transept as one. The altar area, with its ground level situated 0.6 m above the nave, and the cloister, with its ground level 0.8 m above the nave, were prospected separately. In order to get results with sufficient vertical range and horizontal definition, the GSSI SIR-3000 system was used with a 270MHz antenna and 512 samples in a 95ns time window saved in 16bits format.

3The basilica was explored using a 0.4 m separation between radargrams and a horizontal resolution of 0.025 m or 40 scans per meter. As a higher resolution was necessary in the nave, an additional perpendicular grid was put down in this area. Time-to-depth conversion was performed with a velocity computed through hyperbolas geometry analysis.

4The data were processed using the time-slice method which gives horizontal sections that supply the archaeological team with precise information.

Results of the prospection

5The SOT team’s experience on similar archaeological sites was very useful for deciding the geometry of processing parameters. Indeed, the thickness of the time window used to create horizontal sections and the radius for interpolation have a straightforward impact on the sharpness and definition of the anomalies.

6Within the first two meters below ground surface a minimum of three successive levels was detected in most of the nave extensions under the current pavement. The processing revealed a group of anomalies (9 and 9’) located under the nave, at a computed depth of 0.9 m below ground surface; the axis of symmetry of these remains is similar to that of the cathedral and would suggest the existence of a separate structure.

7Further processing reduced the thickness of the time window used for time-slice computation to 6 cm, making it possible to describe the said structure. It features a semicircular perimeter which stands against a massive structure at the northern end and is in connection with another structure (9’) oriented east to west with a possible opening or door.

8Although the described shapes are well defined horizontally, their vertical definition is irregular, which could mean that the structure is not well preserved or that the superposition of various phases of construction makes the identification of each structure and of the relations between structures difficult.

9In addition to the architectural analysis and interpretation, the results will have other applications. Validating this information with archaeological intervention on selected locations, the team of archaeologists will have a tool for planning future research with predefined goals.

Data filtering and analysis

10For testing statistical, analytical and imaging procedures, part of a dataset collected in the nave was used, featuring 0.4 m spacing between transects in both x and y directions, at 40 scans/m (0.025m per scan).

11As thickness of the time window has an impact on the generated slice maps, the sensitivity to thickness had to be studied. Time-slices are usually generated computing the mean value of squared amplitude. Other statistical operators were tested in order to improve structure definition: these included standard deviation of amplitude, squared amplitude and magnitude, on non-interpolated data and on combined X and Y directions.

12Besides the sensitivity to thickness, under the 2 m there is a loss of intensity and/or of signal quality. Geostatistical and statistical flowcharts were applied in order to improve data quality. They consist in generating a correction index based on the filtering of statistical 2D maps and applying this index to the 3D amplitude cube.

Figure 1: Tarragona Cathedral survey project, GPR survey results – time-slice views. Time-slice from 21.8-23.1ns (Calculated 0.90-0.96 m depth). Detail of central building at the same depth (3X3 low-pass filtered).

Figure 1: Tarragona Cathedral survey project, GPR survey results – time-slice views. Time-slice from 21.8-23.1ns (Calculated 0.90-0.96 m depth). Detail of central building at the same depth (3X3 low-pass filtered).

Figure 2: Tarragona Cathedral survey project, GPR survey results – 3D isosurface views.

Figure 2: Tarragona Cathedral survey project, GPR survey results – 3D isosurface views.

Nave isosurface 60 % – 10 to 46ns ; Nave isosurface 60 % – 22 to 46ns ; Nave isosurface 60 % – 32 to 46ns ; Detail of area ; Altar isosurface 75 % – 20 to 90ns.

Top of page

Bibliography

Macias, J. M., Menchon, J. J., Muñoz, A. and Teixell, I. 2007. Excavaciones en la Catedral de Tarragona y su entorno: avances y retrocesos en la investigación sobre el culto Imperial. Culto Imperial: política y poder, actas del Congreso Internacional (Mérida 2006), L’Erma di Bretschneider, 765-787. Roma.

Macias, J. M., Menchon, J. J., Muñoz, A. and Teixell, I., 2007. L’Arqueologia de la Catedral de Tarragona. La memòria de les pedres. In La Catedral de Tarragona. Sede, 10 anys del Pla Director de Restauració, 151-213.

Conyers, L. B., 2004.Ground-penetrating Radar for Archaeology. AltaMira Press: Walnut, Creek, CA.

Goodman, D, Nishimura, Y and Rogers, J.D., 1995. GPR time-slice in archaeological prospection. Archaeological Prospection, 3: 85–89.

Sandjivy, L., 1984. Analyse krigeante des données géochimiques: étude d’un cas monovariable dans le modèle stationnaire. Sciences de la terre, 18: 141-172.

Matheron, G., 1965.Les variables régionalisées et leur estimation: une application de la théorie des fonctions aléatoires aux sciences de la nature. Paris, Masson.

Top of page

List of illustrations

Title Figure 1: Tarragona Cathedral survey project, GPR survey results – time-slice views. Time-slice from 21.8-23.1ns (Calculated 0.90-0.96 m depth). Detail of central building at the same depth (3X3 low-pass filtered).
URL http://journals.openedition.org/archeosciences/docannexe/image/1803/img-1.png
File image/png, 245k
Title Figure 2: Tarragona Cathedral survey project, GPR survey results – 3D isosurface views.
Caption Nave isosurface 60 % – 10 to 46ns ; Nave isosurface 60 % – 22 to 46ns ; Nave isosurface 60 % – 32 to 46ns ; Detail of area ; Altar isosurface 75 % – 20 to 90ns.
URL http://journals.openedition.org/archeosciences/docannexe/image/1803/img-2.png
File image/png, 153k
Top of page

References

Bibliographical reference

Robert Tamba, Roger Sala and Ekhine García, “Testing the use of geostatistical and statistical methods to improve data visualization.
Case study on GPR survey of Tarragona Cathedral”
ArcheoSciences, 33 (suppl.) | 2009, 335-338.

Electronic reference

Robert Tamba, Roger Sala and Ekhine García, “Testing the use of geostatistical and statistical methods to improve data visualization.
Case study on GPR survey of Tarragona Cathedral”
ArcheoSciences [Online], 33 (suppl.) | 2009, Online since 30 October 2011, connection on 18 April 2024. URL: http://journals.openedition.org/archeosciences/1803; DOI: https://doi.org/10.4000/archeosciences.1803

Top of page

About the authors

Robert Tamba

Sot prospecció arqueològica (tamba_of@yahoo.fr)

By this author

Roger Sala

Sot prospecció arqueològica (roger_sala_bar@yahoo.es)

By this author

Ekhine García

Sot prospecció arqueològica (ekhinegarcia@yahoo.com)

By this author

Top of page

Copyright

CC-BY-NC-ND-4.0

The text only may be used under licence CC BY-NC-ND 4.0. All other elements (illustrations, imported files) are “All rights reserved”, unless otherwise stated.

Top of page
Search OpenEdition Search

You will be redirected to OpenEdition Search