Introduction

1A survey involving both surface and cross borehole Electrical Resistivity Tomographies (ERTs) is described. It was conducted at various parts of the western wall of the city of Thessaloniki (N. Greece) aiming to estimate the extent of the walls’ foundations.

2The Thessaloniki city walls have been initially erected during the Hellinistic and early Roman period. A second phase, which is partly preserved until today, was build during the Byzantine period. It runs parallel to the older one and at parts the two walls coincide. It had an average height of 10 meters and a thickness of 4.5 m. The wall is founded within alluvium sediments mostly clays and sands.

3The present study was undertaken in the framework of the construction of the new Thessaloniki Underground, since the planned Metro line crosses the walls (Fig. 1) and the scheduled Metro station. Because of the urban environment, extensive use of surface geophysical methods was not possible. To complement the data and infer more safe conclusions, two pairs of boreholes were drilled and instrumented to obtain cross-hole ERT data.

Figure 1: Photo showing the location of the Walls, the boreholes and the surface ERT lines.

Figure 1: Photo showing the location of the Walls, the boreholes and the surface ERT lines.

Surface ERT measurements

4Surface ERT measurements were carried out at lines crossing the wall over selected areas in which the wall has partly collapsed or is completely covered by pavement (profiles S1-S4 in Fig. 1). Measurements were obtained using the pole-dipole and the Wenner Schlumberger arrays using 24 electrodes spaced 1 m apart. Since the topography was rough, terrain had to be included into the inversion procedure. Bentonite and flat base electrodes were used in combination with conventional spike electrodes to avoid damaging the antiquities and the pavement (Athanasiou et al., 2007; Tsokas et al., 2008).

5The surface ERT measurements were processed using a smoothness constrained inversion algorithm (Tsourlos, 1995) and the inversion results are depicted in Figure 2. The RMS errors were particularly low (< 4%) indicative of the generally good data quality. The wall signature is depicted clearly as high resistivity anomaly in all sections. In sections S2 and S3 the wall’s foundation seems to be reaching at depths of 4-5 m below ground level.

Figure 2: Inversion results of sections S1-S4 (see Fig. 1 for location).

Figure 2: Inversion results of sections S1-S4 (see Fig. 1 for location).

Borehole ERT Measurements and Interpretation

6Two pairs of typical geotechnical boreholes (B1-2 and B3-4 in Fig. 1) having an approximate length of 15 m were drilled and instrumented. The distance between the holes was approximately 7 m and the inter-electrode spacing was set to 0.5 m using 24 electrodes in each hole. The borehole cable was custom made by assembling 24 standard PVC coated 0.5 mm cooper conductors of variable length.

7A thin plastic pipe was lowered into the hole and the cable was simultaneously attached to the pipe using tag tapes. Every 0.5 meters the pipe lowering procedure was stopped in order to attach an electrode which was an aluminium tag tape (2 cm width) which encircled the pipe. At a final stage the hole was filled by a mixture of water, sand and bentonite. Finally a connector was fitted to every conductor (channel) and through a specially constructed box and connection cables; it was possible to connect the conductors to the automated resistivity instrument’s switch box.

8For every borehole pair several cross-hole ERT data sets employing the dipole-dipole, pole-pole and pole-dipole arrays were collected. Although, using also surface electrodes would be desirable, it was not made possible at the current state due to technical reasons. Given however that the ERT cable installation is permanent, this was left to be done in the near future.

9Generally contact resistances were low (< 0.5 kOhm) and data repeatability using reciprocal measurement tests was excellent. The data sets were inverted using a smoothness constrained algorithm (Tsourlos, 1995) and the RMS errors were generally below 3 %. The inversion results of the crossed dipole-dipole array are presented here.

10In Figure 3 (left hand side), the inversion results for the set obtained from boreholes B1-B2 is shown. In this particular area there are two walls as it was seen by an open excavation near-by and the respective surface ERT S1 (Fig. 2): to the left the “newest” Byzantine wall while to the centre the classical wall. High resistivity areas at the central part correspond to the “classical” wall and it seems that its foundations reach to the depth of 6 meters being in agreement with what the archaeologists were expecting.

Figure 3: Inversion results of ERT B1-B2 (left) and ERT B3-B4 (right).

Figure 3: Inversion results of ERT B1-B2 (left) and ERT B3-B4 (right).

11Figure 3 (right hand side) shows also the inversion results for the tomography across the boreholes B3-B4. The high resistivity area at the central part is the wall’s foundations. Note that in this case the Byzantine and classical walls coincide. The foundations of the wall seem to extend at a depth of approximately 5 m below the ground level. This result is in very good agreement with the respective surface ERT results (see section S3 in Fig. 2), regarding both the actual size and depth extent of the wall as well as regarding other features such as the resistive top layer to the left of the wall.

Conclusions

12The use of combined tomographic methods to asses the depth of the wall foundations can produce reliable results in a situation where excavation is not possible. The borehole ERTs results are in agreement with the existing information and the conventional surface ERTs.

Top of page

Bibliography

Athanasiou, E., Tsourlos, P. I., Vargemezis, G., Papazachos, C. B., Tsokas, G. N., 2007.Nondestructive DC resistivity surveying using flat-base electrodes. Near Surface Geophysics, 5 (4): 243-272.

Tsourlos, P., 1995. Modelling interpretation and inversion of multielectrode resistivity survey data. Ph.D. Thesis, University of York.

Tsokas, G. N., Tsourlos, P. I., Vargemezis, G., Novack, M., 2008. Non destructive ERT for indoors investigations: the case of Kapnikarea Church in Athens. ArchaeologicalProspection, 15: 47-61.

Top of page

List of illustrations

Title Figure 1: Photo showing the location of the Walls, the boreholes and the surface ERT lines.
URL http://journals.openedition.org/archeosciences/docannexe/image/1865/img-1.jpg
File image/jpeg, 412k
Title Figure 2: Inversion results of sections S1-S4 (see Fig. 1 for location).
URL http://journals.openedition.org/archeosciences/docannexe/image/1865/img-2.png
File image/png, 234k
Title Figure 3: Inversion results of ERT B1-B2 (left) and ERT B3-B4 (right).
URL http://journals.openedition.org/archeosciences/docannexe/image/1865/img-3.png
File image/png, 485k
Top of page

References

Bibliographical reference

Panagiotis Tsourlos and Gregory N. Tsokas, “Tomographic Imaging of Ancient Wall Foundations in Thessaloniki, North Greece”ArcheoSciences, 33 (suppl.) | 2009, 371-373.

Electronic reference

Panagiotis Tsourlos and Gregory N. Tsokas, “Tomographic Imaging of Ancient Wall Foundations in Thessaloniki, North Greece”ArcheoSciences [Online], 33 (suppl.) | 2009, Online since 30 October 2011, connection on 29 March 2024. URL: http://journals.openedition.org/archeosciences/1865; DOI: https://doi.org/10.4000/archeosciences.1865

Top of page

About the authors

Panagiotis Tsourlos

Exploration Geophysics Lab., School of Geology, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece

By this author

Gregory N. Tsokas

Exploration Geophysics Lab., School of Geology, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece

By this author

Top of page

Copyright

CC-BY-NC-ND-4.0

The text only may be used under licence CC BY-NC-ND 4.0. All other elements (illustrations, imported files) are “All rights reserved”, unless otherwise stated.

Top of page
Search OpenEdition Search

You will be redirected to OpenEdition Search